View Single Post
  #26  
Old 08-19-2007, 12:14 PM
drh4683's Avatar
drh4683 drh4683 is offline
VideoKarma Member
 
Join Date: Jan 2003
Location: Chicago, IL
Posts: 2,094
Estate sale find: 8-18-07

Picked up a 1971 Zenith console color set. Was a great find as early 70's zeniths are my favorites and are hardest to find plus being a dual speaker danish modern cabinet design made it even better. model B4744W, 12B14C50 chassis. This is a hybrid chassis for course but still had plenty of tubes in it. The set was at 2234 Grove Ave, Berwyn, IL. Found it in the basement. Luckily a clean dry basement. The set was pretty dusty and didnt work that great when I found it. After looking around the basement, I found the original operation manual for the set.
I never had a 12B14C50 chassis before and have been wanting to find one. After looking at the service manual, the 12B14C50 was noted as the "top of the line TV chassis for 1971".
It has the ultramatic UHF tuner, which I have never had on a manual tuning set before.
While looking around the rest of the house, I found some other manuals that helped me determine what TV's they had. I found the manual and schematic for a rca CTC-11, which was long gone. I think its safe to assume this '71 zenith replaced the CTC-11 which would have been about 10 years old at the time. That CTC-11 was probably put into the basement. Then I found another manual for a 1990 Zenith console with the purchase date and info written on it. I think that TV replaced this '71 zenith, that was put into the basement in 1990 unused. The CTC-11 was probably thrown away in 1990 when this zenith was brought down.

This is just a guess of course. The '71 zenith was a well used TV, but well cared for. The CRT was dim when I found it, so it probably got 19 good years of service. Most tubes were changed over the years, but the CRT is still original. The set does not appear to have had any serious work done to it, the chassis appears to have never been pulled out.

So basically, this TV survived 17 extra years and should have been thrown away in '90. This would have been typical. In the early 90's I found lots of early 70's zeniths at the resale shop by my old home and at the curb. Im glad they decided to keep it.

I went over the entire chassis. I didnt need to rejuv the tube, just raised the heaters up to about 8 volts for 15 minutes and brought the CRT back pretty good, even at a cold start up its about 7.8 out of 10, green gun being the weakest at about 7.3. Tuner got pulled to check out the ultramatic drive components. Everything looked good and moved fine.
VHF tuner was pretty dirty and intermittent.
One thing was impressed me was the light up UHF scale for presets of the ultramatic tuner. The dial scale lights up when you push in the UHF fine tuner. Never seen anything like it before. Also, the VHF and UHF dial indicators are direct view, but angle up tward the operator. You can see in the one photo, the indicators do not face out perpindicular to the front of the TV. Also to note, the Outter knobs are the channel changer, while the inner knobs are for fine tuning. Complete opposite from how most TV's were designed.

This is the first year zenith used the V series CRT's, 25VAMP22 (more rectangular) The color circuits had some issues, hue was not adjustable and when you pulled you activated the auto tint gaurd, the screen went completely green. After looking at the 9-47 duramodule, the tech. incorrectly plugged one of the tint leads one pin off on the duramod. Corrected that and it worked just fine. Zenith also had that non tamper HV protection cover soldered over the HV control. As the set ages, component values change and the HV goes way up. The HV was at about 28 KV and still had plenty of range with the control centered bringing it back to a correct 25KV at zero beam.
Zenith manual tells you to jumper various connections if the HV is too high or low, yet if the HV control goes bad, just "reset the HV to 25 KV and resolder the plate". So you can safely readjust the HV without causing other circuits to go out of tolerance. Zenith only did this for two years then went back to the exposed HV control, probably because the techs didnt like it. Zenith also had that "hollow shaft" HV pots back in the 60's color sets. All in efforts to help keep the customer from touching the control as he would exposed himself to x-ray if brought up too high.
Ive had the same exact issue with the 12A12C52 chassis. Just unsolder the cover plate, bring the control back a touch and you're back to 25KV.

This set is working really nice now. I took it apart and cleaned it up, checked some tubes as nothing else was really wrong. Typical zenith, they just keep going!
Attached Images
File Type: jpg 71zen2c.jpg (110.6 KB, 51 views)
File Type: jpg 71zen2a.jpg (68.6 KB, 65 views)
File Type: jpg 71zen2b.jpg (94.5 KB, 24 views)
File Type: jpg 71zen2e.jpg (57.0 KB, 47 views)
File Type: jpg 71zen2f.jpg (65.3 KB, 28 views)
File Type: jpg 71zen2g.jpg (93.8 KB, 45 views)
File Type: jpg 71zen2h.jpg (65.9 KB, 289 views)
File Type: jpg 71zen2i.jpg (55.5 KB, 23 views)
File Type: jpg 71zen2j.jpg (88.2 KB, 50 views)
File Type: jpg 71zen2k.jpg (97.9 KB, 34 views)
File Type: jpg 71zen2l.jpg (93.0 KB, 31 views)
File Type: jpg 71zen2m.jpg (63.8 KB, 36 views)
File Type: jpg 71zen2o.jpg (37.2 KB, 80 views)
__________________
I tolerate the present by living in the past...
To see drh4683's photo page, click here
To see drh4683's youtube page, click here

Last edited by drh4683; 08-19-2007 at 12:32 PM.
Reply With Quote