If the CRT is dark at the neck, there are two possible causes:
1. CRT filament is open (bye bye CRT)
2. filament supply voltage is not present.
If its the supply voltage, then go to the power supply. If this set has a filament transformer it may be bad. If this set has a filament winding in the flyback, you will either need to purchase a new flyback or add a filament transformer .
Another thing that may cause the filament to be dark is a poor connection at the neck of the CRT. If possible, remove the connector from the CRT neck. Whether its just a connector, or a circuit board is attached to it, make sure nothing is securing it to the neck before removing it.
What you are looking for is corrosion or carbon on the pins of the tube and the socket it fits in . It will be green and powdery looking or black if its carbon. If any exists, use a pipe cleaner with a good contact cleaner (I like caig De-oxit) in the socket. Use very fine sandpaper (1000 - 2000 grit) to burnish the pins of the tube.
Also, if this has a circuit board attached to the CRT connector, check to make sure there are no bad solder connections. The solder connections are the silvery dots that have a pin or wire attached to. if there are any cracks in the solder around where the CRT socket is it may be the cause of your dead tube.
I hope this of some help. I'm more of a techy guy, and not that good at explaining these sorts of things. Good luck on getting your vintage set running. Sounds like it has served you well up until this point.
__________________
Jordan
|