Old 05-27-2007, 04:18 PM
old_tv_nut's Avatar
old_tv_nut old_tv_nut is offline
See yourself on Color TV!
 
Join Date: Jul 2004
Location: Rancho Sahuarita
Posts: 7,814
The main risk in a non-defective set was to servicemen running the sets with shielding removed and being constantly exposed day in and day out. The main risk in defective sets was from a defective regulator or rectifier tube (can't remember if it was either or both). The defect was a tilting of the internal parts of the tube, which allowed X-rays to be emitted around the metal parts in the bottom of the tube. Which side of the set would be "hot" depended on the mounting of the emitting tube. In some sets, this would be downward, so a kid sitting up close with feet under a consolette would get exposed. The tube problems were discovered and voluntarily reported by the manufacturer in parallel with instituting new QC measures to prevent defective tubes from being manufactured or sold. Even though the problem was fixed immediately as it was discovered, additional tests were added for all TV sets. I recall tests being done when I was at Motorola, but in general, the levels were so low as to be hard to measure. The introduction of solid-state rectifiers along with greater X-ray blocking in CRT glass eliminated the problem for good. (Now, of course, there are questions about CRT disposal because of the high lead content.)