This sounds like a thermal problem...not likely tube related as a weak tube will be weak all the time and will not gradually change over the course of an hour.
It sounds like the set is losing horizontal drive signal...some freeze spray applied around components in the horizontal oscillator area would probably be helpful in troubleshooting.
Also check for microcracks in the solder on the circuit board.
Since you have the SAMS it would be good to check all the voltages in the horizontal oscillator circuit and the output tube screen, grid and cathode voltages. (Don't measure the plate voltage with the lead connected as the HV will fry the meter.)