pac.attack76
10-08-2025, 07:21 PM
No power at all. Removed back and metered both fuses and beeps on both. Do these have to be removed to test or is there something else I need to be looking at? No bulging caps.
|
View Full Version : 2011 Panasonic Viera TC-P50X3 50" plasma dead pac.attack76 10-08-2025, 07:21 PM No power at all. Removed back and metered both fuses and beeps on both. Do these have to be removed to test or is there something else I need to be looking at? No bulging caps. pac.attack76 10-12-2025, 08:42 AM I did also notice when plugging into outlet, there's a relay click but no lights or power. kf4rca 10-12-2025, 11:28 AM Check the Mosfets in the PS for short. pac.attack76 10-12-2025, 11:34 AM Check the Mosfets in the PS for short. Ok, thanks! pac.attack76 11-03-2025, 09:38 AM Check the Mosfets in the PS for short. Only time I've ever had dealing with mosfets was in an xbox 360. Im a bit confused as I tested what I thought were mosfets but the only one that beeped on the multimeter was actually a shottky barrier diode. What should I be looking for on here? I think I'm missing something 😕 Alex KL-1 11-04-2025, 08:01 AM Only time I've ever had dealing with mosfets was in an xbox 360. Im a bit confused as I tested what I thought were mosfets but the only one that beeped on the multimeter was actually a shottky barrier diode. What should I be looking for on here? I think I'm missing something 😕 Probably it will have a permanent resistive load in the PSU (but only older PSU's have it), then the solution for testing is desoldering. Or, is a special MOSFET with a Schottky diode in antiparallel, normally used for syncronous rectifying. pac.attack76 11-04-2025, 08:47 AM Probably it will have a permanent resistive load in the PSU (but only older PSU's have it), then the solution for testing is desoldering. Or, is a special MOSFET with a Schottky diode in antiparallel, normally used for syncronous rectifying. So I should take it off the heat sink and remove from board before testing? It's a YG862C15. Alex KL-1 11-05-2025, 07:16 AM So I should take it off the heat sink and remove from board before testing? It's a YG862C15. According with the data, is simply a Schottky diode. But in doubt, desolder some terminal, or remove them. To be sure if is not a subsequent circuit having trouble (like a post buck regulator going do-do). pac.attack76 11-05-2025, 07:21 AM Ok, hopefully today, I can get around to it. pac.attack76 11-05-2025, 09:19 AM According with the data, is simply a Schottky diode. But in doubt, desolder some terminal, or remove them. To be sure if is not a subsequent circuit having trouble (like a post buck regulator going do-do). Would you be able to mark all of the ones I should remove as I'm not sure which ones to check? https://flic.kr/p/2rDEQSL Alex KL-1 11-05-2025, 12:57 PM Would you be able to mark all of the ones I should remove as I'm not sure which ones to check? https://flic.kr/p/2rDEQSL Outrageously busy now but... you can measure all, note that Schottky will have a typical low value of measurement (in the diode scale of a DMM), like 80-160 (after some seconds for charging the caps), you can need to remove only the ones that measure far from it (eg. if one measures 30, or short - near zero). Ordinary P-N diodes will measure 450-700. pac.attack76 11-05-2025, 09:28 PM Outrageously busy now but... you can measure all, note that Schottky will have a typical low value of measurement (in the diode scale of a DMM), like 80-160 (after some seconds for charging the caps), you can need to remove only the ones that measure far from it (eg. if one measures 30, or short - near zero). Ordinary P-N diodes will measure 450-700. Ok, I'll check in the morning. pac.attack76 11-06-2025, 09:34 AM Outrageously busy now but... you can measure all, note that Schottky will have a typical low value of measurement (in the diode scale of a DMM), like 80-160 (after some seconds for charging the caps), you can need to remove only the ones that measure far from it (eg. if one measures 30, or short - near zero). Ordinary P-N diodes will measure 450-700. Ok, i tested all the "similar in appearance" components mounted to 3 different heat sinks and got the following readings from each: 204 - YG862C15 689 - K3607 2.793 - YG971S8 847 - 06N903 1.180 - K8A50D 961 - K8A50D 1.676 - K20A60U 2.746 - Y0972S6 Not sure if I did this right but I had my meter set to diode testing. Triangle pointing to a line. Alex KL-1 11-07-2025, 06:53 AM At least none indicates shorting. In relay clicks, my fear is taht some another board have trouble. This is way outside my field since I changed the job just when LCD and plasma started to proliferate. pac.attack76 11-07-2025, 09:51 AM At least none indicates shorting. In relay clicks, my fear is taht some another board have trouble. This is way outside my field since I changed the job just when LCD and plasma started to proliferate. Yeah, alot of changes since crt design. Most techs never moved on. |