Using those freebee Harbor Freight DVMs as panel meters

Have an old homebrewed linear adjustable power supply with a meter that was hard to figure out. Volts and amps output, switchable. I figured I could use one of those freebee Harbor Freight DVM to replace the old meter, to become this power supply's panel meter. The power supply can provide up to 27VDC at around an amp. I picked two ranges I'm going to use, 200VDC and 10A. Then I had to figure out how to do the switching the big knob usually does, so I could have a two position switch. I found I could do this with a 4 pole double throw slide switch. Two of the poles would have wires connected to all 3 connections, and the other two poles just two wires each. Another normally switched connection was always connected, so a solder jumper took care of that. Below are some pictures detailing the meter wiring and switching.



The power supply connections to the meter goes as such: The positive output goes to the volts input jack. This positive also goes to the external output jack of the power supply cabinet. The negative output goes to the common jack of the meter. And the negative output of the power supply cabinet goes to the current jack on the meter. There's a current shunt inside the meter that measures voltage developed across this shunt. Thus I don't need to plug or unplug anything when I want to switch from volts to amps on the meter.

There's a trimpot on the DVM's circuit board that I used to adjust the voltage reading. And as the current reading was a little high compared to other DVMs I have, I was able to get it close by adding a 0.1ohm resistor in parallel with the shunt.

I needed to provide a separate 9V power supply to the DVM. Used the guts of a wall wart, with a voltage regulator added to it to get a steady 9V source.

Attached Images
File Type: jpg psdvma.jpg (41.7 KB, 82 views)
File Type: jpg psdvmv.jpg (45.0 KB, 81 views)
File Type: jpg meterwiring.jpg (48.5 KB, 84 views)
File Type: jpg metermodeswitch.jpg (49.9 KB, 79 views)
File Type: jpg image_11746.jpg (62.6 KB, 77 views)
__________________
Reply With Quote
  #2  
Old 09-28-2016, 10:23 PM
Electronic M's Avatar
Electronic M Electronic M is offline
M is for Memory
 
Join Date: Jan 2011
Location: Pewaukee/Delafield Wi
Posts: 14,758
I've been meaning to construct a metered isolated variac...This would make a nice cheap meter setup.
__________________
Tom C.

Zenith: The quality stays in EVEN after the name falls off!
What I want. --> http://www.videokarma.org/showpost.p...62&postcount=4
Reply With Quote
  #3  
Old 09-29-2016, 02:56 PM
wa2ise's Avatar
wa2ise wa2ise is offline
VideoKarma Member
 
Join Date: Dec 2002
Location: USA
Posts: 3,147
Quote:
Originally Posted by Electronic M View Post
I've been meaning to construct a metered isolated variac....
Those meters don't have AC amps. Just DC.
__________________
Reply With Quote
  #4  
Old 09-30-2016, 10:54 AM
dieseljeep dieseljeep is offline
VideoKarma Member
 
Join Date: Jul 2010
Posts: 7,562
Quote:
Originally Posted by wa2ise View Post
Have an old homebrewed linear adjustable power supply with a meter that was hard to figure out. Volts and amps output, switchable. I figured I could use one of those freebee Harbor Freight DVM to replace the old meter, to become this power supply's panel meter. The power supply can provide up to 27VDC at around an amp. I picked two ranges I'm going to use, 200VDC and 10A. Then I had to figure out how to do the switching the big knob usually does, so I could have a two position switch. I found I could do this with a 4 pole double throw slide switch. Two of the poles would have wires connected to all 3 connections, and the other two poles just two wires each. Another normally switched connection was always connected, so a solder jumper took care of that. Below are some pictures detailing the meter wiring and switching.



The power supply connections to the meter goes as such: The positive output goes to the volts input jack. This positive also goes to the external output jack of the power supply cabinet. The negative output goes to the common jack of the meter. And the negative output of the power supply cabinet goes to the current jack on the meter. There's a current shunt inside the meter that measures voltage developed across this shunt. Thus I don't need to plug or unplug anything when I want to switch from volts to amps on the meter.

There's a trimpot on the DVM's circuit board that I used to adjust the voltage reading. And as the current reading was a little high compared to other DVMs I have, I was able to get it close by adding a 0.1ohm resistor in parallel with the shunt.

I needed to provide a separate 9V power supply to the DVM. Used the guts of a wall wart, with a voltage regulator added to it to get a steady 9V source.

I was thinking about doing, that very same thing, ages ago!
I'm going to mount the meter to the front panel of my variable power supply and drill holes in the back of the plastic case to run the meter and power supply leads and leave the selector switch in place.
There's several ways of doing it and you inspired us to practice our ingenuity
Reply With Quote
  #5  
Old 09-30-2016, 01:15 PM
Electronic M's Avatar
Electronic M Electronic M is offline
M is for Memory
 
Join Date: Jan 2011
Location: Pewaukee/Delafield Wi
Posts: 14,758
Quote:
Originally Posted by wa2ise View Post
Those meters don't have AC amps. Just DC.
I've seen AC amps cheapies elsewhere....Hell I may have one that had it's ohms range cooked (from measuring voltage in ohms mode) that I could use....Trouble is I have so much crap (mine and others') to fix that I don't have time to build/modify stuff and won't for a while....I'm thinking of doing a second pick at that TV place in In., and declaring TV purchasing hiatus for a few months till I can widdle stocks/backlog down to a manageable level.
__________________
Tom C.

Zenith: The quality stays in EVEN after the name falls off!
What I want. --> http://www.videokarma.org/showpost.p...62&postcount=4
Reply With Quote
Audiokarma
Reply


Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -5. The time now is 03:58 AM.



Powered by vBulletin® Version 3.8.4
Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
©Copyright 2012 VideoKarma.org, All rights reserved.