66M Resistor Cleaning

There's a 66meg resistor in the ctc2B that pulled my focus down. Checked its resistance with two DMM with 30 and 40 meg max. Both measured around 24meg. It was in there since '54 and gathered lotsa crud on its surface. I removed it and wiped it down with languor thinner. It now exceeded the range of my meters so I stuck it back in. Got expected focus voltage range so I assumed the cleaning worked. Lotsa luck..........Tom