Check for filament voltage between pins 1 and 11 on the 11 pin adapter cable.

If present, suspect a problem in the metering circuit.

If not present, look for a fault in the filament transformer, filament selector switch, life test switch, or filament set pot and associated 15K resistor.

The "CRT Test" and "Beam Builder" lights are fed from a separate transformer than the CRT filament.