CTC-4 problem

I got the voltage down now but the plate's still going red. Other voltages are pretty much ballpark--(-58 and -20V). This is just bench testing the chassis at this stage and the CRT is not in the circuit yet. Also, I note that I replaced the 3V, 1000mfd cap with a polarized electrolytic; the schematic calls for a non-polarized unit. Suggestions? Was there a way to connect two polarized electrolytics to get a non-polarized configuration? Seems as if I read something on this somewhere but can't remember where. Checking the AES catalog, I can't seem to find anything but polarized.

Thanks,
Michael