Agreed 100% !

My gas fired forced hot air furnace would kill a main circuit board every 5 years of so for the same failure every time , the tiny relay the manufacturer used to control the 1/2 HP blower motor would have it's contacts literally evaporated . After 3 boards in like 13 years I finally bought a properly rated "Omron" relay which I mounted to the side of the control box , threw a couple of snubbers across the contacts , and that relay (with it's see through plastic case) has barely even pitted it's contacts some 10 years later .

And a fridge connected to the internet ? Oh no no no , not in any house I own !

And the same goes for the crapper when they finally come up with a way to hook THAT up to the net as well ...