Quote:
Originally Posted by miniman82 View Post
19kv with the HV pot maxed and the cry disconnected means a shunt regulator problem, does it have one of those 100meg resistors in the circuit somewhere? Might have drifted. You need to take readings of the regulator tube cathode and grid, post them here. The bias on the regulator is certainly funny...it's dragging your HV down for some reason.
it has 2- 1.5 meg resistors and i checked them and they drifted very little 1.6 and 1.59 not so bad within range. i already posted the voltage findings and the ma from all the few wires coming off the 6bk4 reg tube. please check further back on this thread for the voltages they are here. i think there were a brown wire, a green wire and i think a yellow coming off that tube.