Phil,

Are you connecting the Sencore from terminal J to ground? The detector circuit output is across J and L. I looked at the CTC4 schematic and the connection of the generator from J to ground may not work because L is floating. Note that L is the sync separator feed. L also attaches to the cathode of the first video stage. V110 is a cathode follower.
The first cathode follower video stage does not invert the signal nor does it provide any voltage gain. It only provides an impedance match to the delay line.
So why not try and attach the generator from L to ground and see if that works? (You might want to DC isolate the connection to L with a 2uF 50v electrolytic with "+" to the cathode of v110).

Cheers,

Terry