Tip on the horizontal hold: the control is a coil, not a pot....So the stop is the knob's pointer hitting the metal tab in the pencil box. To get more range pull the knob out past the point where the pointer hits the stop then turn it some more. The knob should have a hex shaft so you could set it up so the pointer is at mid mech range at the center of the electrical sync range. I can't remember changing caps having much effect on H hold range in Zeniths.
|