Quote:
Originally Posted by Tom Albrecht View Post
...the flyback heating occurs whether the 3A3 is connected or not, so it seems to rule out something loading the HV as a cause.
True Tom, but the 1X2B is still in the circuit, which drives the focus circuit, which is why Nick is so adamant about replacing the convergence transformer. One never knows for sure what is wrong until it's fixed of course...

Pete

Tom, I just read your latest post. Yes, I agree that removing the focus rectifier should remove a convergence transformer short from the flyback; I did not see a 1X2B reference earlier in the thread.